Calibrate Service by Technicians.

logoflukeEarthline provider process inspection before delivery to users. And after-sales service. The tool is worldwide brand as the standard Fluke products from the United States. In order to create Confidence for the product. Benefit for patients and user to reduce treatment failure and the risk of loss. Preventive maintenance Service. Verify the accuracy of the device to other agencies. Or importer to every need. Measurement precision and accuracy. The list standards devices are as follows.

INCU

INCU  (Incubator Analyzer) Using a calibrated Infant Incubator, and infant Radiant Warmer By verify follow the function. Monitoring humidity. Airflow rates that refer to Standards for incubator. Sound Check volume of sound inside the cabinet to verify the quality of the incubator, that is not harmful to children and appropriate to the growth of children. Temperature 4 points separate the distribution of temperature at various points (head, body, foot) that is different than the standard or not. However, because the temperature at each point. Directly affect the safety of children.

 

Natal Care+

 

DPM2 Plus

DPM2

 


DPM2 Plus
  The calibration pressure can be measured both at the liquid | gas can be measured up to 4 units (cmH2, inH2O, psi, mmHg) to measure flow rate with Parabolic Flow to determine the standard of Suction pressure ,suction machine or other suction device that is accurate pressure refer to the safety standards.

Fluke Hart Scientific

Lab

logoflukehart
Fluke Hart Scientific 4180 

Precision Infrared Calibrator.

 

Use to verify the accuracy of the Infrared thermometer. Verify the quality of the goods before – after sale .Usage can be measured from – 15 C – 120 C and can check infrared equipment onsite, if devices are larger. Features are both the high precision and compact. Support is ideal, the infrared industry, and the precision of medical (Medical Device).

Non-Invasive Blood Pressure

Non-Invasive Blood Pressure
Simulator and Tester

Signal simulator blood pressure NIBP Simulators. Is use for calibration of the pressure signal is modeled by a Non-Invasive Blood Pressure Blood pressure measuring devices. Can generally be defined as Systolic, Diastolic and Heart Rate, and continue to work with in terms of the Static Pressure.

neoBLUE® radiometer

neoBLUE® radiometer

To accurately measure the intensity of neoBLUE LED Phototherapy Systems providesprecise measurement of light in the blue spectrum to ensure optimal phototherapy treatment.

Olympic Bili-Meter™

Olympic Bili-Meter™

Battery-operated radiometer measures irradiance (blue spectrum) of fluorescent and halogen phototherapy lamps in µw/cm²/nm. Large, easy-to-read digital display. Memory feature retains last reading. Factory-certified to NIST standards. Includes B-22 sensor and battery.

CritiCool®

The CritiCool device functions as a control unit and a cooling pump. The control unit monitors the patient’s core

temperature through specific probes and uses control algorithms to reach the desired temperature set point.

Therefore, we must always calibrate core and surface temperature,all sensors,thermostat and pressure for accuracy.

All items will be checked for the standard QC.
And calibrated before every run to you. To standards and traceability. To support compliance with the ISO.